Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 2651, 2024 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-38302683

RESUMEN

Cardiovascular disease (CVD) represents one of the main causes of mortality worldwide and nearly a half of it is related to ischemic heart disease (IHD). The article represents a comprehensive study on the diagnostics of IHD through the targeted metabolomic profiling and machine learning techniques. A total of 112 subjects were enrolled in the study, consisting of 76 IHD patients and 36 non-CVD subjects. Metabolomic profiling was conducted, involving the quantitative analysis of 87 endogenous metabolites in plasma. A novel regression method of age-adjustment correction of metabolomics data was developed. We identified 36 significantly changed metabolites which included increased cystathionine and dimethylglycine and the decreased ADMA and arginine. Tryptophan catabolism pathways showed significant alterations with increased levels of serotonin, intermediates of the kynurenine pathway and decreased intermediates of indole pathway. Amino acid profiles indicated elevated branched-chain amino acids and increased amino acid ratios. Short-chain acylcarnitines were reduced, while long-chain acylcarnitines were elevated. Based on these metabolites data, machine learning algorithms: logistic regression, support vector machine, decision trees, random forest, and gradient boosting, were used for IHD diagnostic models. Random forest demonstrated the highest accuracy with an AUC of 0.98. The metabolites Norepinephrine; Xanthurenic acid; Anthranilic acid; Serotonin; C6-DC; C14-OH; C16; C16-OH; GSG; Phenylalanine and Methionine were found to be significant and may serve as a novel preliminary panel for IHD diagnostics. Further studies are needed to confirm these findings.


Asunto(s)
Enfermedades Cardiovasculares , Isquemia Miocárdica , Humanos , Serotonina , Aminoácidos , Metabolómica/métodos , Aminoácidos de Cadena Ramificada/metabolismo , Isquemia Miocárdica/complicaciones , Enfermedades Cardiovasculares/etiología
2.
Bull Exp Biol Med ; 167(1): 91-96, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31177467

RESUMEN

Comparative mass spectrometric analysis of protein composition was carried out in 36 blood plasma specimens from patients with renal cell carcinoma and 20 specimens from donors. Analysis of protein composition of plasma specimens devoid of the major protein fractions showed a 20-50% higher level of protein identifications in patient' specimens. Specimens of the control and experimental series were similar by protein composition, 70-80% identifications in experimental and control series coinciding. High similarity of biological processes with participation of the proteins identified in both series was observed. The greater part of proteins in both series were located extracellularly and were exosomal (specimens from renal cancer patients) or vesicular (specimens from healthy volunteers).


Asunto(s)
Proteínas Sanguíneas/análisis , Carcinoma de Células Renales/sangre , Neoplasias Renales/sangre , Proteoma/análisis , Biomarcadores de Tumor/sangre , Cromatografía Liquida , Femenino , Humanos , Masculino , Proteómica/métodos , Espectrometría de Masas en Tándem
3.
J Virol Methods ; 251: 99-105, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29042217

RESUMEN

In the present study, the possibility of hepatitis C virus core antigen (HCVcoreAg) detection in buffer solution, using atomic force microscope chip (AFM-chip) with immobilized aptamers, has been demonstrated. The target protein was detected in 1mL of solution at concentrations from 10-10М to 10-13М. The registration of aptamer/antigen complexes on the chip surface was carried out by atomic force microscopy (AFM). The further mass-spectrometric (MS) identification of AFM-registered objects on the chip surface allowed reliable identification of HCVcoreAg target protein in the complexes. Aptamers, which were designed for therapeutic purposes, have been shown to be effective in HCVcoreAg detection as probe molecules.


Asunto(s)
Aptámeros de Nucleótidos/metabolismo , Microscopía de Fuerza Atómica/métodos , Proteínas del Núcleo Viral/análisis
4.
Patol Fiziol Eksp Ter ; 61(2): 101-7, 2017.
Artículo en Ruso | MEDLINE | ID: mdl-29215851

RESUMEN

The purpose of the research consisted in detection of fluctuation of brightness temperature (TSHF) of water in the area of the temperature Т = 42°Ð¡ (that is critical for human) during its evaporation by SHF radiometry. Methods: Monitoring of the changes in brightness temperature of water in superhigh frequency (SHF) range (3.8-4.2 GHz) near the phase transition temperature of water Т = 42°Ð¡ during its evaporation in the cone dielectric cell. The brightness temperature measurements were carried out using radiometer. Results: Fluctuation with maximum of brightness temperature was detected in 3.8-4.2 GHz frequency range near at the temperature of water Т = 42°Ð¡. It was characteristic for these TSHF fluctuations that brightness temperature rise time in this range of frequencies in ~4°Ð¡ temperature range with 0.05-15°Ð¡/min gradient and a sharp decrease during 10 s connected with measuring vapor conditions. Then nonintensive fluctuation series was observed. At that, the environment temperature remained constant. Conclusion: The significant increasing in brightness temperature of water during its evaporation in SHF range near the temperature of Т ~42°Ð¡ were detected. It was shown that for water, ТSHF pull with the amplitude DТSHF ~4°C are observed. At the same time, thermodynamic temperature virtually does not change. The observed effects can be used in the development of the systems for diadnostics of pathologies in human and analytical system.


Asunto(s)
Calor , Microondas , Agua/química
5.
J Mol Neurosci ; 62(3-4): 420-429, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28730336

RESUMEN

According to WHO data, about 67 million people worldwide are affected by autism, and this number grows by 14% annually. Among the possible causes of autism are genetic modifications, organic lesions of the central nervous system, metabolic disorders, influence of viral and bacterial infections, chemical influence to the mother's body during pregnancy, etc. The conducted research shows that research papers published until today do not name any potential protein markers that meet the requirements of the basic parameters for evaluating the efficiency of disease diagnostics, in particular high sensitivity, specificity, and accuracy. Conducting proteomic research on a big scale in order to detect serologic markers of protein nature associated with development of autism spectrum disorders seems to be highly relevant.


Asunto(s)
Trastorno del Espectro Autista/sangre , Trastorno del Espectro Autista/genética , Autoanticuerpos/sangre , Biomarcadores/sangre , Citocinas/sangre , Humanos , Péptidos/sangre , Serotonina/sangre
6.
Biomed Khim ; 62(4): 439-46, 2016 May.
Artículo en Ruso | MEDLINE | ID: mdl-27562998

RESUMEN

A combination of (atomic force microscopy)-based fishing (AFM-fishing) and mass spectrometry allows to capture protein molecules from solutions, concentrate and visualize them on an atomically flat surface of the AFM chip and identify by subsequent mass spectrometric analysis. In order to increase the AFM-fishing efficiency we have applied pulsed voltage with the rise time of the front of about 1 ns to the AFM chip. The AFM-chip was made using a conductive material, highly oriented pyrolytic graphite (HOPG). The increased efficiency of AFM-fishing has been demonstrated using detection of cytochrome b5 protein. Selection of the stimulating pulse with a rise time of 1 ns, corresponding to the GHz frequency range, by the effect of intrinsic emission from water observed in this frequency range during water injection into the cell.


Asunto(s)
Citocromos b5/química , Espectrometría de Masas/métodos , Microscopía de Fuerza Atómica/métodos , Proteoma/química , Campos Electromagnéticos , Humanos , Microscopía de Fuerza Atómica/instrumentación
7.
Patol Fiziol Eksp Ter ; 60(1): 94-8, 2016.
Artículo en Ruso | MEDLINE | ID: mdl-29215256

RESUMEN

A method for detection of cancer-associated protein D-NFATc1 in serum using nanowire (NW) biosensor based on field-effect nanotransistor is developed. Field-effect nanotransistor was fabricated on the basis of «silicon-on-insulator¼ structures. For the biospecific detection of target protein, the NW surface was modified with aptamers against the target protein. Using the 3 um-NW enabled to obtain stable source-drain characteristics and to register D-NFATc1 in serum at concentration of 2.5 x 1014 M in the mode of drain-source current vs. gate voltage characteristics measurements. Data collection in the mode of drain-source current vs. gate voltage characteristics measurements was carried out with the use of high-speed data collection system running TURBO NBS software.


Asunto(s)
Técnicas Biosensibles , Factores de Transcripción NFATC/sangre , Nanocables , Proteínas de Neoplasias/sangre , Programas Informáticos , Transistores Electrónicos , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Humanos , Sensibilidad y Especificidad
8.
Biochem Biophys Rep ; 5: 285-289, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28955835

RESUMEN

Microwave radiation at 3.4-4.2 GHz frequency of the cytochrome P450 CYP102 A1 (BM3) solution was registered during the lauric acid hydroxylation reaction. The microwave radiation generation was shown to occur following the addition of electron donor NADPH to a system containing an enzyme and a substrate. The radiation occurs for the enzyme solutions with enzyme concentrations of 10-8 and 10-9 Ðœ. The microwave radiation effect elicited by the aqueous enzyme solution was observed for the first time. The results obtained can be used to elaborate a new approach to enzyme systems research, including studying of the mechanism of interaction of a functioning enzyme system with microenvironment.

9.
Patol Fiziol Eksp Ter ; 60(4): 174-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-29244941

RESUMEN

The purpose: The purpose of this research consisted in monitoring of brightness temperature of the suspension of follicular thyroid carcinoma cells during the necrosis of these cells in superhigh frequency (SHF) range. Methods: The monitoring of the change in the ratio between brightness temperatures TSHF and TIR values during the necrosis of these cells. The object of study was follicular thyroid carcinoma cells suspension prepared with use of Versene solution and 0.25% trypsin solution. The cells were precipitated by centrifugation and re-suspended in culture medium. The measurements of brightness temperatures were carried out with use of radiothermoimeter. SHF range was 3.4-4.2 GHz, and infrared (IR) range was 8-13 mm. The temperature of the suspension was maintained at 37.5°Ð¡. Results: It was found that upon the necrosis in the suspension of cells, an increase in brightness temperature in 3.4-4.2 GHz range (SHF range) occurs, while brightness temperature of the medium in the IR range does not change. Conclusion: The monitoring of necrosis of follicular thyroid carcinoma cells was carried out by SHF-radiothermometry. It was shown that during the necrosis the change of non-equilibrium state of cell medium occurs, that results in the change in the ratio between TSHF and TIR. During the necrosis, the brightness temperature in SHF range (TSHF) increases.


Asunto(s)
Adenocarcinoma Folicular/metabolismo , Adenocarcinoma Folicular/patología , Ondas de Radio , Termometría/métodos , Neoplasias de la Tiroides/metabolismo , Neoplasias de la Tiroides/patología , Línea Celular Tumoral , Humanos
10.
Biomed Khim ; 61(4): 462-7, 2015.
Artículo en Ruso | MEDLINE | ID: mdl-26350736

RESUMEN

The nanowire (NW) detection is one of fast-acting and high-sensitive methods allowing to reveal potentially relevant protein molecules. A NW biosensor based on the silicon-on-insulator (SOI)-structures was used for biospecific label-free detection of NFAT 1 (D-NFAT 1) oncomarker in real time. For this purpose, SOI-nanowires (NWs) were modified with aptamers against NFAT 1 used as molecular probes. It was shown that using this biosensor it is possible to reach the sensitivity of ~10(-15) M. This sensitivity was comparable with that of the NW biosensor with immobilized antibodies used as macromolecular probes. The results demonstrate promising approaches used to form the sensor elements for high-sensitive disease diagnostics.


Asunto(s)
Aptámeros de Nucleótidos/química , Técnicas Biosensibles/instrumentación , Factores de Transcripción NFATC/análisis , Nanocables/química , Proteínas de Neoplasias/análisis , Anticuerpos Monoclonales/química , Aptámeros de Nucleótidos/síntesis química , Técnicas Biosensibles/economía , Técnicas Electroquímicas , Humanos , Límite de Detección , Dióxido de Silicio/química , Soluciones , Succinimidas/química
11.
Biomed Khim ; 61(3): 363-72, 2015.
Artículo en Ruso | MEDLINE | ID: mdl-26215414

RESUMEN

A method of atomic force microscopy-based fishing (AFM fishing) has been developed for protein detection in the analyte solution using a chip with an immobilized aptamer. This method is based on the biospecific fishing of a target protein from a bulk solution onto the small AFM chip area with the immobilized aptamer to this protein used as the molecular probe. Such aptamer-based approach allows to increase an AFM image contrast compared to the antibody-based approach. Mass spectrometry analysis used after the biospecific fishing to identify the target protein on the AFM chip has proved complex formation. Use of the AFM chip with the immobilized aptamer avoids interference of the antibody and target protein peaks in a mass spectrum.


Asunto(s)
Aptámeros de Nucleótidos/química , Proteína gp120 de Envoltorio del VIH/análisis , Ácidos Nucleicos Inmovilizados/química , Microscopía de Fuerza Atómica/métodos , Anticuerpos Inmovilizados/química , Aptámeros de Nucleótidos/análisis , Proteína gp120 de Envoltorio del VIH/inmunología , Microscopía de Fuerza Atómica/instrumentación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
12.
Biomed Khim ; 61(2): 239-53, 2015.
Artículo en Ruso | MEDLINE | ID: mdl-25978390

RESUMEN

Achievement of the concentration detection limit for proteins at the level of the reverse Avogadro number determines the modern development of proteomics. In this review, the possibility of approximating the reverse Avogadro number by using nanotechnological methods (AFM-based fishing with mechanical and electrical stimulation, nanowire detectors, and other methods) are discussed. The ability of AFM to detect, count, visualize and characterize physico-chemical properties of proteins at concentrations up to 10(-17)-10(-18) M is demonstrated. The combination of AFM-fishing with mass-spectrometry allows the identification of proteins not only in pure solutions, but also in multi-component biological fluids (serum). The possibilities to improve the biospecific fishing efficiency by use of SOMAmers in both AFM and nanowire systems are discussed. The paper also provides criteria for evaluation of the sensitivity of fishing-based detection systems. The fishing efficiency depending on the detection system parameters is estimated. The practical implementation of protein fishing depending on the ratio of the sample solution volume and the surface of the detection system is discussed. The advantages and disadvantages of today's promising nanotechnological protein detection methods implemented on the basis of these schemes.


Asunto(s)
Microscopía de Fuerza Atómica/métodos , Proteínas/análisis , Animales , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Ensayo de Inmunoadsorción Enzimática , Humanos , Límite de Detección , Espectrometría de Masas , Microscopía de Fuerza Atómica/instrumentación , Técnicas de Sonda Molecular , Nanotecnología/métodos , Nanocables , Proteínas/metabolismo , Resonancia por Plasmón de Superficie/métodos
13.
Biofizika ; 60(1): 80-7, 2015.
Artículo en Ruso | MEDLINE | ID: mdl-25868344

RESUMEN

The change in temperature is one of the factors affecting the activity of enzymes. In this work thermal denaturation and aggregation of cytochrome P450 BM3 were studied by atomic force microscopy. To determine specific temperature transitions the fluorescence analysis was used. In the low melting temperature range, 10-33 degrees C, a decrease in the fluorescence intensity of aromatic residues was observed with an increase in the fluorescence intensity of flavin groups. Protein melting in this range indicated three narrow S-shaped cooperative transitions at temperatures 16, 22 and 29 degrees C. Atomic force microscopy analysis in this temperature range showed that the shape of BM3 molecules remained globular in the form of compact objects (heights h < 7 nm, lateral dimensions d < 50 nm), but protein oligomeric state changed. The first two transitions were accompanied by a decrease in the degree of oligomerization and the third one was accompanied by its increase.


Asunto(s)
Sistema Enzimático del Citocromo P-450/química , Sistema Enzimático del Citocromo P-450/ultraestructura , Calor , Microscopía de Fuerza Atómica , Multimerización de Proteína , Estructura Terciaria de Proteína
14.
Biomed Khim ; 60(1): 28-50, 2014.
Artículo en Ruso | MEDLINE | ID: mdl-24749246

RESUMEN

The atomic-force microscopy-based method of irreversible chemical AFM-fishing (AFM-IF(Ch)) has been developed for the detection of proteins at ultra-low concentrations in solution. Using this method, a very low concentration of horseradish peroxidase (HRP) protein (10(-17) M) was detected in solution. A theoretical model that allows the description of obtained experimental data, is proposed. This model takes into consideration both the transport of the protein from the bulk solution onto the AFM-chip surface and its irreversible binding to the activated area.


Asunto(s)
Avidina/aislamiento & purificación , Proteínas del Huevo/aislamiento & purificación , Peroxidasa de Rábano Silvestre/aislamiento & purificación , Microscopía de Fuerza Atómica/métodos , Simulación por Computador , Cinética , Dispositivos Laboratorio en un Chip , Microscopía de Fuerza Atómica/instrumentación , Modelos Químicos , Unión Proteica , Soluciones
15.
Biofizika ; 56(5): 939-44, 2011.
Artículo en Ruso | MEDLINE | ID: mdl-22117449

RESUMEN

An approach to measure the activity of single oligomers of the heme-containing enzyme the cytochrome P450 CYP102A1 (CYP102A1) by atomic force microscopy (AFM) has been developed. It was found that the amplitude of fluctuations of the height of single CYP102A1 molecules performing the catalytic cycle is twice as great as the amplitude of fluctuations of the height of the same enzymes in the inactive state. It was shown that the amplitude of height fluctuations of a CYP102A1 protein globule depends on temperature, the maximum of this dependence being observed at 22 degrees C. The activity of a single CYP102A1 molecule in the unit amplitude of height fluctuations of a protein globule reduced to the unit time was 5+/-2 Ac. The elasticity of a single protein molecule was measured from the deformation of this molecule by the action of an AFM probe. The use of AFM probes of different geometry made i t possible t o determine t he integral andlocal Young's modulus for the monomers of the protein putidaredoxin reductase from the cytochrome P450 CYP101 (P450cam)-containing monooxigenase system, which were 37+/-117 and 1+/-3 MPa, respectively.


Asunto(s)
Proteínas Bacterianas/ultraestructura , Sistema Enzimático del Citocromo P-450/ultraestructura , Complejos Multiproteicos/ultraestructura , NADPH-Ferrihemoproteína Reductasa/ultraestructura , Proteínas Bacterianas/química , Sistema Enzimático del Citocromo P-450/química , Hidroxilación , Microscopía de Fuerza Atómica/métodos , Complejos Multiproteicos/química , NADPH-Ferrihemoproteína Reductasa/química
16.
Biomed Khim ; 56(1): 26-39, 2010.
Artículo en Ruso | MEDLINE | ID: mdl-21328909

RESUMEN

Possibility of detection and identification of hepatitis C viral particles with mass spectrometry (MS) in combination with atomic force microscopy (AFM) had been investigated. AFM/MS approach is based on two technologies: (1) AFM-biospecific fishing that allows to detect, concentrate from solution and to count protein complexes on a surface of AFM-nanochip; (2) mass spectrometric identification of these complexes. AFM-biospecific fishing of HCVcoreAg from solution was carried onto surface of AFM-nanochips with immobilized anti-HCVcoreAg. It was shown that HCVcoreAg/anti-HCVcore(im) complexes were formed onto AFM-nanochips in quantity sufficient for mass spectrometric identification. Thus, AFM/MS approach allows to identify fragments of hepatitis C virus fished onto a surface of AFM-nanochip from serum.


Asunto(s)
Hepacivirus , Virión , Secuencia de Aminoácidos , Anticuerpos Monoclonales , Hepacivirus/inmunología , Hepatitis C/sangre , Antígenos de la Hepatitis C/análisis , Antígenos de la Hepatitis C/inmunología , Humanos , Dispositivos Laboratorio en un Chip , Microscopía de Fuerza Atómica , Datos de Secuencia Molecular , Proteínas Recombinantes/análisis , Proteínas Recombinantes/inmunología , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Espectrometría de Masas en Tándem , Virión/inmunología , Virología/métodos
17.
Biomed Khim ; 55(6): 689-701, 2009.
Artículo en Ruso | MEDLINE | ID: mdl-20469717

RESUMEN

The aim of the study was to demonstrate the possibility of detection of serological markers, containing the hepatitis B surface antigen (HBsAg) and hepatitis C virus core-antigen (HCVcoreAg) in human serum, by use of a new atomic force microscopy (AFM)-based nanotechnological approach. In this study, the immobilization on AFM-chip of antibodies against the hepatitis B virus surface antigen (anti-HBsAg) as well as the antibodies against the hepatitis C virus core antigen (anti-HCVcoreAg) was performed. It was shown that such approach enables to detect: HBsAg, HCVcoreAg and the viral fragments containing these antigens in the serum. Comparative analysis of detection of HBsAg- and HCVcoreAg-containing particles by use of the AFM method vs. traditional methods (ELISA, PCR) has demonstrated the 75% coincidence of results between the AFM and the latter two methods.


Asunto(s)
Antígenos de Superficie de la Hepatitis B/sangre , Hepatitis B/sangre , Antígenos de la Hepatitis C/sangre , Hepatitis C/sangre , Microscopía de Fuerza Atómica/métodos , Biomarcadores/sangre , Ensayo de Inmunoadsorción Enzimática , Hepacivirus , Anticuerpos contra la Hepatitis B/química , Virus de la Hepatitis B , Anticuerpos contra la Hepatitis C/química , Humanos , Reacción en Cadena de la Polimerasa , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...